Budownictwo i Inżynieria Środowiska
2015.205, DOI: 10.7862/rb.2015.205
RESISTANCE AND DURABILITY ANALYSIS OF STEEL SUPPORTING STRUCTURE ON THE BELL TOWER OF ST. TRINITY CHURCH IN KROSNO
Marta RYMAR, Lucjan ŚLĘCZKA
DOI: 10.7862/rb.2015.205
Abstract
The paper describes the analysis of steel structure, supporting three bells
in the belfry of St. Trinity Church in Krosno. The structure is dated from 1928
and has a form of riveted space truss, with slender members. The total mass
of all bells, coming from the 17th century, is nearly equal to 4200 kilograms,
so the dynamic forces coming from bells swinging are quite large. The paper describes
specific problems associated with assessing the resistance of old steel
structure, treated as a relic. The analysis covered technical condition assessment
of the structure, evaluation of actions and environmental influences, mechanical
parameters prediction of steel and rivets by non-destructive methods and also
static and dynamic analysis of the structure. According to many years of exploitation,
the fatigue verifications were also performed using the classification method.
References
[1] Agocs Z., Ziółko J., Vičan J., Brodniansky J.: Assessment and refurbishment of steel
structures. Spon Press, Taylor & Francis Group, Ister Science Ltd., 2005.
[2] Bachmann H. et al.: Vibration problems in structures. Practical guidelines. Birkhauser
Verlag, 1995.
[3] Bryła S.: Podręcznik budownictwa żelaznego. Nakładem Księgarni Polskiej Bernarda
Połonieckiego, 1924.
[4] Czapliński K.: Dawne wyroby ze stopów żelaza. Dolnośląskie Wydawnictwo Edukacyjne,
Wrocław, 2009.
[5] DIN 4178 Glockentürme. Deutsches Institut für Normung, 2005.
[6] Gosowski B., Organek P.: Use of the hardness test in-situ for evaluation of strength
of steel from the early 20th century. Metal Structures – Scientific Technical Conference,
Kielce-Suchedniów, 2-4 July 2014, pp.139-142.
[7] Kühn B. et al.: Assessment of existing steel structures: Recommendations for estimation
of remaining fatigue life. European Commission Joint Research Centre,
2008.
[8] PN-EN 1990 Eurocode - Basis of structural design. PKN, Warszawa 2004.
[9] PN-EN 1993-1-1 Eurocode 3: Design of steel structures - Part 1-1: General rules
and rules for buildings. PKN, Warszawa 2006.
[10] PN-EN 1993-1-9 Eurocode 3: Design of steel structures - Part 1-9: Fatigue. PKN,
Warszawa 2007.
[11] Pszenicki A.: Tablice momentów statycznych i bezwładności blach i kątowników
używanych w mostownictwie i budownictwie stalowem. Komitet Wydawniczy Podręczników
Akademickich przy Ministerstwie W.R i O.P., Warszawa 1932.
[12] Rapp P.: Historical bells – mechanics and drive problems. Journal of Heritage Conservation,
No. 40/2014, pp. 41-57.
[13] Rozporządzenie Ministra Robót Publicznych z dnia 18 czerwca 1929 r. zawierające
przepisy o granicach wytrzymałości materiałów i konstrukcyj budowlanych.
About this Article
TITLE:
RESISTANCE AND DURABILITY ANALYSIS OF STEEL SUPPORTING STRUCTURE ON THE BELL TOWER OF ST. TRINITY CHURCH IN KROSNO
AUTHORS:
Marta RYMAR (1)
Lucjan ŚLĘCZKA (2)
AUTHORS AFFILIATIONS:
(1) Historic Preservation Officer in Krosno
(2) Politechnika Rzeszowska
JOURNAL:
Budownictwo i Inżynieria Środowiska
2015.205
KEY WORDS AND PHRASES:
bell tower, static analysis, dynamic analysis, fatigue
FULL TEXT:
http://doi.prz.edu.pl/pl/pdf/biis/406
DOI:
10.7862/rb.2015.205
URL:
http://dx.doi.org/10.7862/rb.2015.205
RECEIVED:
2015-05-26
COPYRIGHT:
Publishing House of Rzeszow University of Technology Powstańców Warszawy 12, 35-959 Rzeszow