Budownictwo i Inżynieria Środowiska
15/117, DOI: 10.7862/rb.2015.117
TREATMENT OF TECHNOLOGICAL WATER FOR THE AEROSPACE INDUSTRY – OPERATING PROBLEMS
Dorota PAPCIAK, Justyna ZAMORSKA, Monika ZDEB
DOI: 10.7862/rb.2015.117
Abstract
The paper presents the water treatment technology for FPI line (Fluorescent Penetrant Inspection) which is used to conduct diagnostic tests in the field of structural cracks, erosion, corrosion, defects of the material, welds cohesion. The problem that occurred during operation of the FPI line was an increase of turbidity and milky colour of water (i.e. white water) in bathtub of the last rinse which caused the formation of deposits on washed parts and hampered diagnostic process. On the basis of the physicochemical and bacteriological analysis the assessment of changes in water quality during the cleaning process was carried out. The problem of the formation of the so-called "white water" was described and solved. An analysis of necessity of water treatment station modernization as well as the legitimacy of the use of the disinfection process were made. The following parameters of water were analysed: pH, turbidity, conductivity, hardness, dissolved oxygen, total organic carbon, permanganate index, SiO2 content, heavy metals contents, and the total number of mesophilic and psychrophilic bacteria. The results of the analyses indicate that the cause of the growth of technological water turbidity on the FPI, is formation of polysilicon acid. Polymerized forms of silicates exist in colloidal form, therefore, the observed phenomenon is the emergence of so-called "white water" and the formation of deposits.
References
[1] Bielański A. General and Inorganic Chemistry. PWN Warsaw 2013 ((in polish).
[2] Flemming H. Microbial growth on ion exchangers, Water Research, Vol. 21, Issue 7, p. 745-756, 1987.
[3] Puszkarewicz A., Kaleta J. Water treatment for special purposes. Publishing House of Technical University of Rzeszów, 2013 (in polish).
[4] http://ce4mro.com/index.php/news [access: 9 April 2015 r ].
[5] http://www.cnde.iastate.edu/etc/engineerin%20study%20fluorescent%20-penetrant.pdf [access: 9 April 2015].
[6] http://www.ndt.net/article/ecndt98/aero/031/031.htm [access: 3 April 2015].
[7] http://www.ndt24.pl/pl/dokumenty/systemy_fpi [access: 3 April 2015].
[8] http://www.radus.pl/pdf/biuletyny/OCZYSZCZANIE_1.pdf [access: 9 April 2015].
About this Article
TITLE:
TREATMENT OF TECHNOLOGICAL WATER FOR THE AEROSPACE INDUSTRY – OPERATING PROBLEMS
AUTHORS:
Dorota PAPCIAK (1)
Justyna ZAMORSKA (2)
Monika ZDEB (3)
AUTHORS AFFILIATIONS:
(1) Rzeszów University of Technology
(2) Rzeszów University of Technology
(3) Rzeszów University of Technology
JOURNAL:
Budownictwo i Inżynieria Środowiska
15/117
KEY WORDS AND PHRASES:
polymerized forms of silicates, water treatment, FPI - Fluorescent Penetrant Inspection
FULL TEXT:
http://doi.prz.edu.pl/pl/pdf/biis/285
DOI:
10.7862/rb.2015.117
URL:
http://dx.doi.org/10.7862/rb.2015.117
COPYRIGHT:
Publishing House of Rzeszow University of Technology Powstańców Warszawy 12, 35-959 Rzeszow