Budownictwo i Inżynieria Środowiska
2014.135, DOI: 10.7862/rb.2014.135
SEASIONAL COLD ACCUMULATOR WITH FREE-COOLING IN AIR CONDITIONING SYSTEMS
Sławomir RABCZAK, Danuta PROSZAK-MIĄSIK, Krzysztof NOWAK
DOI: 10.7862/rb.2014.135
Abstract
One of the ways to reduce the consumption of traditional energy sources is the use of seasonal cold accumulator that takes advantage of the geographical location in the country and allows, during the winter season, from November to March, accumulate cold because of lower ambient temperature in these months. This leads to saving a significant amount of electricity and reduce operating refrigerant, which is dangerous for the environment. This paper presents a method for determining the size of cold storage with charging devices as chiller and dry-cooler. The approximate costs of device operation including the time of framework of these components on costs of device operation including the time of framework of these components have been obtained. Design seasonal cold accumulator allows to conclude that this solution has a number of economic and ecological advantages. Due to the seasonal tank design the saves on chiller, which under normal circumstances would have been selected for the highest hourly energy demand, which means that the device should be several times larger than the device that was used in the project. By selecting a small chiller the environment from hazardous refrigerants is protected, which are chlorofluorocarbons, specifically in the case of refrigerant called R- 410A.
References
[1] Hasnain S.M.: Review on sustainable thermal energy storage technologies. Part I:
Heat storage materials and techniques. Energy Research Institute, King Abdulaziz
City for Science and Technology. P.O. Box 6086, Riyadh 11442, Saudi Arabia.
[2] Lewandowski W.M.: Proekologiczne źródła energii odnawialnej. WNT, Warszawa
2001.
[3] Mehling H., Cabeza L.F.: Heat and cold storage with PCM. Springer 2008.
[4] PN-EN ISO 13790 November 2008: Energetyczne właściwości użytkowe budynków
Obliczanie zużycia energii na potrzeby ogrzewania i chłodzenia.
[5] Rozporządzenie Ministra Infrastruktury z dnia 6 listopada 2008 r. w sprawie metodo-
logii obliczania charakterystyki energetycznej budynku i lokalu mieszkalnego lub
części budynku stanowiącej samodzielną całość techniczno-użytkową oraz sposobu
sporządzania i wzorów świadectw ich charakterystyki energetycznej.
About this Article
TITLE:
SEASIONAL COLD ACCUMULATOR WITH FREE-COOLING IN AIR CONDITIONING SYSTEMS
AUTHORS:
Sławomir RABCZAK (1)
Danuta PROSZAK-MIĄSIK (2)
Krzysztof NOWAK (3)
AUTHORS AFFILIATIONS:
(1) Politechnika Rzeszowska
(2) Politechnika Rzeszowska
(3) Politechnika Rzeszowska
JOURNAL:
Budownictwo i Inżynieria Środowiska
2014.135
KEY WORDS AND PHRASES:
free-cooling, cold accumulator, air-conditioning, seasional storage
FULL TEXT:
http://doi.prz.edu.pl/pl/pdf/biis/161
DOI:
10.7862/rb.2014.135
URL:
http://dx.doi.org/10.7862/rb.2014.135
RECEIVED:
2014-10-21
COPYRIGHT:
Publishing House of Rzeszow University of Technology Powstańców Warszawy 12, 35-959 Rzeszow